Application
Telecommunication maintenance, CATV maintenance, fiber optic laboratory testing, other fiber optic measurements
Features
*User auto-calibration function* Convenient LCD display with optional backlight. The LCD screen allows nighttime operation.
*Power measurements in dBm or mW and insertion loss in dB
*Low battery consumption, more than 240 hours of continuous operation with three 1.5V alkaline batteries*. The auto power-off function can be enabled or disabled within 10 minutes.
Technical Parameters
| PON module: | 3213 | 3213A | 3213AV | 3213AP |
| Upstream 1310nm measurement |
| Zona de paso (nm) | 1260 nm a 1360 nm |
| Measurement range (dBm) | -40 dBm~+10 dBm |
| Output power (max) | 15 dBm |
| Aislamiento a 1490/1550 (dB) | >40 dB |
| Burst mode measurement error; downstream 1490nm measurement | <±0.5 dB |
| Zona de paso (nm) | 1470 nm a 1505 nm |
| Measurement range (dBm) | -40 dBm~+10 dBm |
| Output power (max) | 15 dBm |
| Aislamiento a 1310/1550 (dB) | >40 dB | |
| Downstream 1550nm measurement | |
| Zona de paso (nm) | 1535 nm a 1570 nm |
| Measurement range (dBm) | -40 dBm~+10 dBm |
| Output power (max) | 25 dBm |
| Aislamiento@(1310/1490nm) | >40 dB |
| Measurement accuracy | ±0.5 dB |
| Linearity (dB) | ±0.1 dB |
| Insertion loss (dB) | <1.5 dB |
| General information | |
| Detector type | InGaAs |
| Optical connector | Universal FC/SC/ST interchangeable adapter /2.5mm |
| Fiber type | SM 9/125 µm |
| Unit de medida | dB/dBm/xW |
| Resolution (dB); Operating voltage (V) | 0,01 dB CC 3,3 V~5,5 V |
| Power supply | 3 x 1.5V batteries |
| Continuous operation time | PON: 90 horas | PON: 90 h OPM: 100h VFL: 50 horas | PON: 90 h VFL: 50 horas | PON: 90 h OPM: 100h |
| Operating Temperature (°C) | -10℃~60℃ |
| Storage Temperature (℃) | -25℃~70℃ |
| Peso (kg) | 423 g | 425 g | 424 g | 424 g |
Frequently Asked Questions
Q: Which wavelengths are supported?
A: Standard models cover 850, 1300, 1310, 1490, 1550 and 1625nm. PON power meters measure 1310/1490/1550 simultaneously for GPON/EPON network testing.
Q: What is the measurement range?
A: Typical range is -70dBm to +10dBm with high accuracy, suitable for both laboratory and field use.
Q: Are calibration reports available?
A: Yes, each meter is factory calibrated and calibration/traceability reports can be provided with the order.
Q: What connector interfaces are supported?
A: Universal SC/FC/ST adapters are included; LC adapters are available on request.
Q: Can I test a live PON signal with the PON model?
A: Yes, the PON power meter simultaneously measures downstream 1490nm, upstream 1310nm and CATV 1550nm signals on a live network without interrupting service.