Application
Fiber optic cable installation and maintenance: ensures fast and accurate optical signal measurement.
Optical network testing: essential for troubleshooting and performance validation in telecommunication networks.
Fiber optic sensor applications: used in fiber optic sensing systems for monitoring and diagnostics.
CATV and broadband network maintenance: facilitates fast and reliable verification of optical connectivity.
Features
1. Support illumination
2. Supports auto power-off.
3. Supports backlight on/off.
4. Supports wavelength memory function.
5. Supports fiber optic job identification
6. Supports customer self-calibration
7. Red light normally blinks and flickers (fault indication)
8. Supports SC, FC and ST interfaces.
9. Compatible with charger/computer power supply (battery power)
10. Supports simultaneous display of linear (mW) and non-linear (dB) readings.
11. Supports RJ45 test
12. Operating time on a full battery charge is 48 hours.
13. Supports PC terminal and real-time operation from mobile phone.
14. Supports three data modes for offline, PC and mobile phone connections.
Technical Index
Technical Parameters
| Wavelength range | 800~1700 |
| Detector type | InGaAs |
| Power measurement range | -70~+3 o -50~+20 |
| Incertidumbre | ±5% |
| Wavelength standard (nm) | 850, 1300, 1310, 1490, 1550, 1625 |
| Screen resolution | Linear indication: 0.1%; logarithmic indication: 0.01dBm |
| Red light working wavelength (nm) | 650 |
| Poder rojo | 1 MW, 5 MW, 10 MW, 20 MW, 30 MW () |
| Frequency identification (Hz) | 0/270/1000/2000 |
| Effective wireless distance (m) | 50 |
| Data storage capacity (pcs) | 65 |
| Input voltage (V) | 3~6 |
| Working temperature (℃) | -10~+60 |
| Storage Temperature (℃) | -25~+70 |
| Auto power-off time (min) | 10 |
| Battery life (h) | ≥48 |
| Instrument size (mm) | 65*30*118 |
| Power supply | 2. Section 7: rechargeable lithium battery and external power input |
| peso (g) | 145 |
Frequently Asked Questions
Q: Which wavelengths are supported?
A: Standard models cover 850, 1300, 1310, 1490, 1550 and 1625nm. PON power meters measure 1310/1490/1550 simultaneously for GPON/EPON network testing.
Q: What is the measurement range?
A: Typical range is -70dBm to +10dBm with high accuracy, suitable for both laboratory and field use.
Q: Are calibration reports available?
A: Yes, each meter is factory calibrated and calibration/traceability reports can be provided with the order.
Q: What connector interfaces are supported?
A: Universal SC/FC/ST adapters are included; LC adapters are available on request.
Q: Can I test a live PON signal with the PON model?
A: Yes, the PON power meter simultaneously measures downstream 1490nm, upstream 1310nm and CATV 1550nm signals on a live network without interrupting service.